| Model |
TC4 5 |
TC4 10 |
TC4 25 |
TC4 50 |
TC4 100 |
TC4 200 |
TC4 300 |
TC4 500 |
TC4 750 |
TC4 1000 |
| Accuracy class: ISO 376 |
1 |
| Accuracy class: ISO 376 |
1 |
| ERRORS |
|
| a) accuracy 0°-120°-240° (b) |
<= ±0.145%(1) |
| b)
interpolation
(fc) |
<= ±0.090%(1) |
| c)
reversibility
(u) |
<= ±0.240%(1) |
| d) zero (fo) |
<= ±0.030% F.S. |
| LINEARITY |
|
| HYSTERESES |
<= ±0,05% F.S. |
| TEMPERATURE EFFECTS (10°C) |
|
| a) on zero |
<= ±0,028% F.S. |
| b) on sensitivity |
<= ±0,024% F.S. |
| TRANSVERSAL PRESSURE EFFECT |
|
| a) with 10% of nominal pressure |
<= ±0,30% F.S. |
| NOMINAL SENSITIVITY |
2mV/V(2) |
| CALIBRATION LIMIT |
<= ±0,1% F.S. |
| INPUT RESISTANCE |
800 ±20  |
430 ±20  |
| OUTPUT RESISTANCE |
705 ±2  |
352 ±2  |
| INSULATION RESISTANCE |
> 5 G  |
| ZERO BALANCING |
<= ±0.5 % F.S. |
| STANDARD POWER SUPPLY |
10 V |
| NOMINAL POWER SUPPLY |
1-15 V |
| MAXIMUM POWER SUPPLY |
18 V |
| MECHANICAL LIMIT VALUES IN |
|
| RELATION TO NOMINAL PRESSURE |
|
| a) service pressure |
120% |
| b) limit pressure |
150% |
| c) breaking pressure |
>300% |
| d) massimo carico trasversale |
100% |
| e) dynamic limit pressure |
75% |
| MAXIMUM RISE TO NOMINAL PRESSURE |
- 0.06 mm |
- 0.09 mm |
- 0.17 mm |
- 0.23 mm |
| STANDARD TEMPERATURE |
+23°C |
| NOMINAL TEMPERATURE RANGE |
-10/+40°C |
| OPERATING TEMPERATURE |
-10/+70°C |
| STOCK TEMPERATURE |
-20/+80°C |
| WEIGHT |
1,60kg |
2,45kg |
5,80kg |
16,5kg |
| PROTECTION CLASS |
IP67 |
| DYNAMOMETRIC MATERIAL |
Stainless steel |
| CABLE LENGTH |
5 m |
(1)
Percentage errors calculated at the value read, min. 1/10 of nominal pressure
(2)
Tests and calibrations after compression with cell assembled on the support and properly tightening the fastening screws
|
|