- Electromechanical rotary table
- Counter support to axial thrusts. Mechanically adjustable for recovery of slacks
- Electrical installation housed in a proof box, according to CEI standard - Voltage 380 V - 50 HZ - Subsidiary 24V - BTS
- Rotary plate in steel Fe 430 B - UNI 7070
- All controls are housed on front panel
|
STATIONS
| Standard |
no. |
4 |
6 |
8 |
12 |
16 |
20 |
24 |
30 |
| Specials |
no. |
2 |
3 |
5 |
7 |
9 |
10 |
|
|
TOLERANCE AND LOAD
| |
OP TR 1 |
OP TR 3 |
OP TR 5 |
OP TR 8 |
OP TR 13 |
OP TR 21 |
OP TR 42 |
| * Tolerance of indexing |
±0,015 su Ø 75 |
±0,015 su Ø 100 |
±0,015 su Ø 100 |
±0,015 su Ø 150 |
±0,015 su Ø 150 |
±0,015 su Ø 200 |
±0,015 su Ø 200 |
| Max axial load of table (N) |
4000 |
4000 |
4000 |
8000 |
8000 |
14000 |
14000 |
| Homocentricity (mm.) |
±0,02 |
±0,02 |
±0,02 |
±0,02 |
±0,02 |
±0,02 |
±0,02 |
* These tolerances are proportional to work diameter of the rotary table
INFORMATION FOR TECHNICAL OFFICE
Values to calculate max rotation speeds

A - Work diameter
B - Moving mass
C - Rotation angle
V - Work speed |
mm =........
kg =........
0° =........
mm/sec =....
|
Work speeds preset on thrust unit, determine time of standoff for rotary table
and complete cycle. |
|
|